Home
About DSL Labs
Contact
|
|
|
|
Typical Environmental Services
Testing Equipment
| Test |
Industry Standard |
Test Conditions |
Equipment |
| HTOL |
JEDEC-STD-22, A108-C |
1000 hours, 125C |
MCC HPB-5A, HPB-5B, Aehr Max 3, 4 Criteria |
| THB |
EIQ/JESD22-A101-B |
1000 hours, biased 85C, 85%RH |
Espec |
| C-Sam |
JEDEC-STD-20 |
Variable |
Hitachi |
| Pre-Conditioning |
JESD-22-A113-D |
Various conditions |
Various |
| I/R(solder) Reflow |
JESD-22-A113-D |
240 or 260C |
Heller |
| Temperature Cycling |
JESD-22-A104 |
Various conditions |
Ransco |
Highly-Accelerated Temp and Humidity Stress Test |
JESD-22-A110-B |
96 hours, biased, 130C/85%RH |
Hirayama |
Accelerated Moisture Resistance-Unbiased HAST |
JESD-22-A118 |
A: 96 hrs, 130C B: 264hrs,110C |
Hirayama |
| High Temperature Storage |
JESD-22-A103-C |
1000 hours, Unbiased, 150C |
Espec |
| Autoclave |
JESD-22-A102-C |
168 hours, 100%RH, 121C, 2atm |
Espec |
| ESD& Latch-Up |
JESD22-C101 JEDEC 78 |
Various Conditions |
Zapmaster MK.4 |
|
|

|
|