Qualifications / Reliability

Qualification and reliability tests ensure proper IC design, package assembly and its integrity by performing electrical stress, thermal stress and mechanical stress tests to identify the occurrence of failures and their severity. DSL Labs' experienced Product Engineers can create a qualification plan for each product's requirements or perform testing to out customers' requirements. Understanding the scope of industry testing standards such as JEDEC, MIL 883, and EIAJ, DSL Labs insures proper compliance where applicable, and also to individual customer's specification




Typical Environmental Services

Testing Equipment
Test Industry Standard Test Conditions Equipment
HTOL JEDEC-STD-22, A108-C 1000 hours, 125C MCC HPB-5A, HPB-5B,
Aehr Max 3, 4 Criteria
THB EIQ/JESD22-A101-B 1000 hours, biased 85C, 85%RH Espec
C-Sam JEDEC-STD-20 Variable Hitachi
Pre-Conditioning JESD-22-A113-D Various conditions Various
I/R(solder) Reflow JESD-22-A113-D 240 or 260C Heller
Temperature Cycling JESD-22-A104 Various conditions Ransco
Highly-Accelerated Temp
and Humidity Stress Test
JESD-22-A110-B 96 hours, biased, 130C/85%RH Hirayama
Accelerated Moisture
Resistance-Unbiased HAST
JESD-22-A118 A: 96 hrs, 130C
B: 264hrs,110C
Hirayama
High Temperature Storage JESD-22-A103-C 1000 hours, Unbiased, 150C Espec
Autoclave JESD-22-A102-C 168 hours, 100%RH, 121C, 2atm Espec
ESD& Latch-Up JESD22-C101
JEDEC 78
Various Conditions Zapmaster MK.4

 